UJI BAKTERI Coliform DAN Escherichia coli PADA AIR MINUM ISI ULANG DAN AIR SUMUR DI KABUPATEN CIREBON
(1) IAIN Syekh Nurjati Cirebon
(2) IAIN Syekh Nurjati Cirebon
(*) Corresponding Author
Abstract
A drinking water is a healthy water that has bacteriological requirement, according to Kepmenkes RI No : 907 tahun 2002. A microbiologial quality testing for drinking water used for testing Coliform bacteria. The purpose of this research is for detecting Coliform bacteria and Escherichia coli on refill drinking water and well water. The water sample taken from refill drinking water and well water in Karyamulya Village RT. 01/RW.11 Cirebon. This research use Laboratory Experiment method, there is MPN (Most Probable Numbers) method that consist of presumption test, affirmation test, and .strengthener test with o,1 ml, 1 ml, and 10 ml water in concentration. The research result shows that refill drinking water positive for containing Coliform bacteria while well water has a negative for containing Coliform bacteria. So, the refill drinking water not suitable for consumption while well water good for consumption.
Â
Air yang digunakan untuk minum adalah air sehat yang harus memenuhi persyaratan Bakteriologi, berdasarkan Kepmenkes RI No: 907 tahun 2002. Pengujian kualitas mikrobiologis air minum digunakan sebagai untuk ujibakteriColiform. Tujuan dilakukannya penelitian ini adalah untuk mendeteksi adanya bakteri Coliformdan E. colidalam uji air isi ulang dan air sumur.Sampel yang diuji diambil dari air isi ulang dan air sumur yang berada di Desa Karyamulya RT.01/RW11 Kabupaten Cirebon. Metode yang dilakukan yaitu Eksperimen Laboratorydengan menggunakan MPN (Most Probable Numbers) yang terdiri dari uji pendugaan, uji penegasan dan uji penguat, dengan konsentrasi larutan 0,1 ml, 1 ml dan 10 ml. Hasil penelitian ini menunjukkan bahwa pada air isi ulang positif mengandung bakteri Coliform, sedangkan pada air sumur negatif bakteri Coliform. Sehingga pada air isi ulang tidak layak konsumsi, sedangkan pada air sumur layak konsumsi.
Â
Keywords
Full Text:
PDFReferences
Andiran G. B., Fatimawali dan Novel S. Kojong. 2014. Analisis Cemaran Bakteri Coliform dan Identifikasi Escherichia coli pada Air Isi Ulang dari Depot di Kota Manado. Jurnal Ilmiah Farmasi Pharmacon Vol. 3 No. 3. Available online: https://ejournal.unsrat.ac.id/index.php/pharmacon/article/view/5450
Chapelle, F, 1993. Groundwater Microbiology and Geochemistry. New York: John Wiley and Sons
Harsojo dan Darsono.2014. Studi Kandungan Logam Berat dan Mikroba pada Air Minum Isi Ulang. Jurnal Ecolab Vol. 8 No 2. Available online: http://ejournal.forda-mof.org/LATIHAN/index.php/JKLH/article/view/1306
Huwaida, R. N. 2014. Faktor-Faktor yang Mempengaruhi Jumlah Escherichia coli Air Bersih pada Penderita Diare di Kelurahan Pakujaya Kecamatan Serpong Utara Kota Tangerang Selatan Tahun 2014. [Skripsi]. Tidak diterbitkan. Fakultas Kedokteran dan Ilmu
Kesehatan Universitas Islam Negeri Syarif Hidayatullah Jakarta.
Kemenkes RI. 2002. Menjaga Air Minum Anda Tetap Aman.Jakarta :Direktorat Jendral Pengendalian Penyakit dan Penyehatan Lingkungan Kemenkes RI
Khairunnisa, C. 2012. Pengaruh Jarak dan Konstruksi Sumur serta Tindakan Pengguna Air terhadap Jumlah Coliform Air Sumur Gali Penduduk di Sekitar Pasar Hewan Desa Cempeudak Kecamatan Tanah Jambo Aye Kabupaten Aceh Utara Tahun 2012. [Tesis]. Medan: Fakultas Kesehatan Masyarakat Universitas Sumatera Utara.
Khoeriyah, A., Anies. 2015. Aspek Kualitas Bakteriologis Depot Air Minum Isi Ulang (DAMIU) di Kabupaten Bandung Barat. Jurnal MKB Vol. 47 No 3. Available online: http://journal.fk.unpad.ac.id/index.php/mkb/article/view/594
Marsono. 2009. Faktor-Faktor Yang Berhubungan Denan Kualtas Bakteriologis Air Sumur Gali di Pemukiman Desa Karangnom Klaten Utara.[Tesis]. Progam Studi Magister Kesehatan Lingkungan. Semarang: Universitas Diponegoro
Nisak, Aulia Jauharum, dkk. 2012. Uji Kualitas Air. [Online]. Tersedia: http://www.scribd.com/ mobile/doc/ujikualitasair.pdf.
Pelczar, M. J. 2009. Dasar-Dasar Mikrobiologi. Jakarta: UI Press.
Perisai P.R., John P., Olivia W. 2014. 2014. Identifikasi Bakteri pada Depot Air Minum Isi Ulang di Kota Manado.UNSRAT Manado : Jurnale-Biomedik Vol. 2 No 2. Available online:
https://ejournal.unsrat.ac.id/index.php/ebiomedik/article/view/5518
Riri Novita, S. 2015.Uji Kualitas Air Sumur Dengan Menggunakan Metode MPN (Most Probable Number. Jurnal Bioilmi Vol. 1 No. 1. Available online: http://jurnal.radenfatah.ac.id/index.php/bioilmi/article/view/1128
Riri Novita, Riri S. 2016.Uji Kualitas AirMinum Isi Ulang di Sekitar Kampus UIN Raden Fatah Palembang. Jurnal Bioilmi Vol. 2 No. 1. Available online: http://jurnal.radenfatah.ac.id/index.php/bioilmi/article/view/1116
Suriawira. U. 1996. Air Dalam Kehidupan dan Lingkungan yang Sehat.Bandung: Alumni Bandung
Suriawira, U. 2008. Mikrobiologi Air dan Dasar-Dasar Pengolahan Secara Biologis. Bandung: Angkasa
Article Metrics
Abstract view : 325 timesPDF - 268 times
Refbacks
- There are currently no refbacks.